Frequently Asked Questions (FAQ)
-
- Correct Clearances
a. Approximate bearing clearance is 0.001″ per inch of rod journal diameter unless otherwise specified by original equipment manufacturer. - Lubricants and Torquing
a. For all rod bolts, both under head and threads should be lubricated with included ARP Ultra-Torque assembly lube.
b. The preferred torquing method is to measure rod bolt stretch, as shown on Table A below. Measure the rod bolt length loose, then progressively tighten to the appropriate stretch recommended, not to exceed the torque figures below.Type of Bolt Recommended Stretch Torque Not to Exceed 3/8 ARP L19 0.0065-0.0070″ 65 FOOT POUNDS 7/16 ARP 2000 0.0055-0.0060″ 75 FOOT POUNDS 7/16 CUSTOM AGE 0.006-0.0065″ 88 FOOT POUNDS 1/2 ARP L19 0.0083-0.0087″ 130 FOOT POUNDS - Additional Notes
a. Pin fit may be required. <0.750″ diameter require 0.0010″-0.0016″; 0.751″-1.100″ require 0.0012″-0.0020″ clearance. Larger pins require more clearance.
b. Rotating assembly should be blueprinted to ensure there are no interference issues.
c. Use engraving or etching tool for numbering rods and caps, not stamps.
d. If any rod bolts permanently stretch after installation or engine has been over-revved, bolts should be replaced.
- Correct Clearances
Use a non-synthetic oil like Rotella T4 15w40. Start the truck and check to make sure it has good oil pressure with a mechanical oil pressure gauge and no leaks.
Run the truck at 1200-1500 rpms for 10-15 mins. Double check everything and take for a test drive.
Try not to hold it at the same rpm for extended amounts of time and don’t let the truck idle a ton.
Change the oil at 800-1,000 miles and refill with non-synthetic oil and change it at 3000 miles. After that, you can switch to a synthetic oil if you choose.
It is normal for it to have a slight amount of blow by at first and use a small amount of oil when the rings are seating.
- Rotate the engine and adjust one cylinder at a time
- When the exhaust valves just begin to open, adjust the intake
- When the intake valves are just past maximum lift, adjust the exhaust
- Intake valve lash .012
- Exhaust valve lash .012
Callies puts a 5mm and 1/4 key in every crank. Fluidamper and factory balancers only have one 5mm slot. So, you remove the 1/4 and only use the 5mm key.